Monarch NICE3000new Err02 — Overcurrent During Acceleration: Causes and Step-by-Step Fix

Err02 on a Monarch NICE3000new integrated controller means the drive detected excessive current while the motor was accelerating. It is one of the most common faults on Chinese elevators using the NICE3000new system, and in most cases it is caused by wiring, motor or encoder issues — not by a failed main board.

Possible Causes

  • Output ground fault or short circuit on the main circuit
  • Motor parameters not tuned (auto-tune not performed after replacement)
  • Incorrect encoder signal or interference
  • Motor phase sequence (U/V/W) reversed

Step-by-Step Troubleshooting

  • 1. Contactor check: verify the run contactor on the controller output side works properly, and that the star-sealing contactor is not shorting the controller output.
  • 2. Motor check: inspect motor cables for surface damage, ground faults and loose connections. Open the motor terminal box and check for copper strands touching ground or an internal short. Verify motor U/V/W phase sequence.
  • 3. Motor parameters: confirm the parameters match the motor nameplate, then repeat motor auto-tuning.
  • 4. Encoder check: verify the pulses-per-revolution setting; run encoder wiring in a separate conduit with single-point shield grounding; verify the encoder shaft is firmly coupled to the motor shaft and rotates smoothly. For induction motors, compare current in open-loop run to judge the encoder.

Pro Tip From the Field

If Err02 appears immediately after replacing a main board or PG card, the most likely cause is missing motor auto-tuning — do the tuning first before swapping more parts.


Still stuck on this fault? Our engineers repair Monarch NICE3000 systems every day. Message us on WhatsApp (+86 139 8566 2489) — send a photo of your board or the fault display, and we will identify the part and guide you through the fix. Every board we sell is 100% run-tested with a 12-month warranty, MOQ 1 piece, and free remote parameter-setup support until your elevator runs.

Browse all codes in our free NICE3000 fault code library.